CAUTION: There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
  1. Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.
    • At analog type tester
    Tester lead Continuity
    -lead +lead
    E P1, P2, P3, P4, P5, P6 Yes
    B None
    P1, P2, P3, P4, P5, P6 E None
    B Yes
    • At digital type tester
    Tester lead Continuity
    -lead +lead
    E P1, P2, P3, P4, P5, P6 None
    B Yes
    P1, P2, P3, P4, P5, P6 E Yes
    B None
Fig 1: Checking Continuity Between Diode Lead And Terminal E Or B