Pressing X Mode Switch Does Not Change The X Mode Display In The Combination Meter And Mode Does Not Switch To X Mode
WARNING: This page is about a different variant/trim than selected.
WIRING DIAGRAM:
<Ref. to WIRING DIAGRAM , CVT Control System.>
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK X MODE SWITCH
.
Connector & terminal (i10) No. 37 - Chassis ground: |
Does the resistance change as below? 1 MΩ or more → less than 10 Ω |
Go to step 5 . | Go to step 2 . |
| 2 CHECK HARNESS BETWEEN COMBINATION METER AND X MODE SWITCH CONNECTOR
. Measure the resistance of harness between combination meter and X mode switch connector. Connector & terminal (i10) No. 37 - (i70) No. 1: |
Is the resistance less than 10 Ω? | Go to step 3 . | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
| 3 CHECK HARNESS BETWEEN COMBINATION METER AND X MODE SWITCH CONNECTOR
. Measure the resistance of harness between X mode switch connector and chassis ground. Connector & terminal (i70) No. 1 - Chassis ground: |
Is the resistance 1 MΩ or more? | Go to step 4 . | Repair the short circuit to ground in harness between combination meter and X mode switch connector. |
| 4 CHECK HARNESS BETWEEN X MODE SWITCH CONNECTOR AND CHASSIS GROUND
. Measure the resistance between combination meter and chassis ground. Connector & terminal (i70) No. 4 - Chassis ground: |
Is the resistance less than 10 Ω? | Repair the poor contact of X mode switch connector. Replace the X mode switch if faulty. <Ref. to X MODE SWITCH .> <Ref. to X MODE SWITCH .> | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
5 RECHECK FAULT
.
|
Is there any fault? | Repair the poor contact of combination meter. Replace the meter case assembly if defective. | The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|