LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Legacy 3.6R Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Continuously Variable Transaxle (CVT) (H4DO)) >> Inhibitor Switch >> Adjustment

Inhibitor Switch: Adjustment

WARNING: This page is about a different variant/trim than selected.
  1. Disconnect the ground cable from battery. <Ref. to BATTERY , NOTE, Repair Contents.>
    NOTE: For model with battery sensor, disconnect the ground terminal from battery sensor.
  2. Release the shift lock using a screwdriver to shift the select lever to the "N" range.
    Fig 1: Releasing Shift Lock Using Screwdriver
    G10274979Courtesy of SUBARU OF AMERICA, INC.
  3. Lift up the vehicle.
  4. Remove the center exhaust pipe. <Ref. to REMOVAL , Center Exhaust Pipe.>
  5. Loosen the two bolts holding the inhibitor switch.
  6. Insert the ST vertically into the holes of the shifter arm and switch body.

    ST 499267300 STOPPER PIN

    Fig 2: Inserting Stopper Pin (499267300) Vertically Into Holes Of Shifter Arm And Switch Body
    G10218581Courtesy of SUBARU OF AMERICA, INC.
  7. Tighten the two bolts holding the inhibitor switch.

    Tightening torque: 

    5 N.m (0.5 kgf-m, 3.7 ft-lb) 

  8. Repeat the inspection of the inhibitor switch. If the inhibitor switch is determined to be "faulty", replace it.