Execution Condition
WARNING: This page is about a different variant/trim than selected.
| Secondary Parameters |
Execution condition |
| Battery voltage |
≥ 10.9 V |
| Starter relay feedback voltage |
< Battery voltage x 0.35 |
| Data received from TCM |
"P" range/"N" range |
| Secondary parameters |
Execution condition |
| Battery voltage |
≥ 10.9 V |
| The number of driving condition change from a) to b) |
= 3 time(s) |
a) Vehicle speed |
≤ 0 km/h (0 MPH) |
and Engine speed |
≥ 550 rpm and ≤ 900 rpm |
b) Vehicle speed |
≥ 64 km/h (39.8 MPH) |
and Engine speed |
≥ 1500 rpm and ≤ 2150 rpm |