Execution Condition
WARNING: This page is about a different variant/trim than selected.
| Secondary parameters | Execution condition |
|---|---|
| Compensation value status for each cylinder = Integrated time after starting operation* | ≥ 400 time(s) (12.8 s) |
| (Refer to Table) * Time is calculated cumulatively (If the secondary parameters are not satisfied for the compensation value status of each cylinder, the integrated time will not be reset) |
COMPENSATION VALUE STATUS FOR EACH CYLINDER
| Secondary parameters | Execution condition |
|---|---|
| Main feedback | In operation |
| Engine speed | ≤ 4000 rpm |
| Engine load | ≥ 0.6 g/rev (0.02 oz/rev) |
| Amount of intake air | ≥ 10 g/s (0.35 oz/s) |