LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Legacy 3.6R Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Emission Control Systems (Aux. Emission Control Devices) (H4DO)) >> Canister >> Installation

Section 11 (Emission Control Systems (Aux. Emission Control Devices) (H4DO)): Canister: Installation

WARNING: This page is about a different variant/trim than selected.
  1. Install the leak check valve assembly to the canister.

    Tightening torque: 

    8 N.m (0.8 kgf-m, 5.9 ft-lb) 

  2. Connect the drain tube (A).
    CAUTION:
    • Check that there is no damage or dust on the quick connector. If necessary, clean the seal surface of the pipe.
    • Make sure that the quick connector is securely connected.
    NOTE: Connect the quick connector as shown in the figure.
    Fig 1: Connecting Quick Connector
    G08315501Courtesy of SUBARU OF AMERICA, INC.
    Fig 2: Identifying Leak Check Valve Assembly Bolts
    G10262347Courtesy of SUBARU OF AMERICA, INC.
  3. Connect the vent tube (A), canister drain tube (B) and purge tube (C), and install the hose clamp (D).
    CAUTION:
    • Make sure there are no damage or dust on connections. If necessary, clean the seal surface of the pipe.
    • Make sure that the quick connector is securely connected.
    NOTE: Connect the quick connector as shown in the figure.
    • Vent tube (A) and canister drain tube (B) (Slider color is red or green.)
      Fig 3: Connecting Quick Connector (Slider Color Red Or Green)
      G11566146Courtesy of SUBARU OF AMERICA, INC.
    • Vent tube (A) and canister drain tube (B) (Slider color is white.)
      Fig 4: Connecting Quick Connector (Slider Color White)
      G11566147Courtesy of SUBARU OF AMERICA, INC.
    • Purge tube (C)
    Fig 5: Disconnecting Quick Connector - Purge Tube (C)
    G11566148Courtesy of SUBARU OF AMERICA, INC.
    Fig 6: Identifying Vent Tube, Canister Drain Tube, Purge Tube And Hose Clamp
    G10262345Courtesy of SUBARU OF AMERICA, INC.
  4. Install the canister protector.

    Tightening torque: 

    8 N.m (0.8 kgf-m, 5.9 ft-lb) 

    Fig 7: Identifying Canister Protector Bolts
    G10262341Courtesy of SUBARU OF AMERICA, INC.
  5. Install the canister.

    Tightening torque: 

    8 N.m (0.8 kgf-m, 5.9 ft-lb) 

  6. Connect the connector (A) to the canister and install the harness clip (B).
    Fig 8: Identifying Canister Bolts, Connector And Clip
    G10262340Courtesy of SUBARU OF AMERICA, INC.
  7. Connect the quick connectors of the vent tube (A), canister drain tube (B) and purge tube (C), and install the tube clamp (D).
    CAUTION:
    • Make sure there are no damage or dust on connections. If necessary, clean the seal surface of the pipe.
    • Make sure that the quick connector is securely connected.
    NOTE: Connect the quick connector as shown in the figure.
    • Vent tube (A) and canister drain tube (B) (Slider color is red or green.)
      Fig 9: Connecting Quick Connector (Slider Color Red Or Green)
      G11566152Courtesy of SUBARU OF AMERICA, INC.
    • Vent tube (A) and canister drain tube (B) (Slider color is white.)
      Fig 10: Connecting Quick Connector (Slider Color White)
      G11566153Courtesy of SUBARU OF AMERICA, INC.
    • Purge tube (C)
    Fig 11: Disconnecting Quick Connector - Purge Tube (C)
    G11566154Courtesy of SUBARU OF AMERICA, INC.
    Fig 12: Identifying Vent Tube, Canister Drain Tube And Purge Tube With Tube Clamp
    G10262339Courtesy of SUBARU OF AMERICA, INC.
  8. Install the rear mud guard LH. Ref. to INSTALLATION , Mud Guard.
  9. Lower the vehicle.
  10. Install the rear wheel LH. Ref. to INSTALLATION , Tire and Wheel.
  11. Connect the ground terminal to battery sensor. Ref. to BATTERY
    NOTE: Repair Contents.