Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when Low side or High side becomes NG.
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Low | |
| Output voltage | < Value of Map 1 |
| High | |
| Output voltage | ≥ Value from Map 2 |
MAP 1 VALUE SPECIFICATION
| Engine speed (rpm) | 1600 | 2000 | 3000 | 4000 | 5000 | 6000 | 6800 |
| Output voltage (V) | 1.86 | 1.99 | 2.23 | 2.43 | 2.59 | 2.73 | 2.83 |
MAP 2 VALUE SPECIFICATION
| Engine speed (rpm) | 525 | 600 | 700 | 800 | 900 | 950 |
| Output voltage (V) | 1.52 | 1.58 | 1.65 | 1.71 | 1.76 | 1.79 |
Time Needed for Diagnosis:
Low: 5000 ms
High: 5000 ms
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.