Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as OFF NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Starter SW1 signal with battery voltage x 0.6 or more (models without push button start) Starter SW2 signal with battery voltage x 0.6 or more (models with push button start) |
Not detected |
Time Needed for Diagnosis: Less than 1 second
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.