  1. Install the leak check valve assembly to the canister.

    Tightening torque: 

    8 N.m (0.8 kgf-m, 5.9 ft-lb) 

  2. Connect the drain tube (A).
    CAUTION:
    • Check that there is no damage or dust on the quick connector. If necessary, clean the seal surface of the pipe.
    • Make sure that the quick connector is securely connected.
    NOTE: Connect the quick connector as shown in the figure.
    Fig 1: Connecting Quick Connector
    G08315501Courtesy of SUBARU OF AMERICA, INC.
    Fig 2: Locating Quick Connector And Bolts
    G10262347Courtesy of SUBARU OF AMERICA, INC.
  3. Connect the vent tube (A), canister drain tube (B) and purge tube (C), and install the hose clamp (D).
    CAUTION:
    • Make sure there are no damage or dust on connections. If necessary, clean the seal surface of the pipe.
    • Make sure that the quick connector is securely connected.
    NOTE: Connect the quick connector as shown in the figure.
    • Vent tube (A) and canister drain tube (B) (Slider color is red or green.)
      Fig 3: Connecting Quick Connector (Slider Color Red Or Green)
      G11585876Courtesy of SUBARU OF AMERICA, INC.
    • Vent tube (A) and canister drain tube (B) (Slider color is white.)
      Fig 4: Connecting Quick Connector (Slider Color White)
      G11585877Courtesy of SUBARU OF AMERICA, INC.
    • Purge tube (C)
    Fig 5: Connecting Quick Connector
    G11585878Courtesy of SUBARU OF AMERICA, INC.
    Fig 6: Vent Tube And Canister Drain Tube
    G10262345Courtesy of SUBARU OF AMERICA, INC.
  4. Install the canister protector.

    Tightening torque: 

    8 N.m (0.8 kgf-m, 5.9 ft-lb) 

    Fig 7: Locating Canister Protector Bolts
    G10262341Courtesy of SUBARU OF AMERICA, INC.
  5. Install the canister.

    Tightening torque: 

    8 N.m (0.8 kgf-m, 5.9 ft-lb) 

  6. Connect the connector (A) to the canister and install the harness clip (B).
    Fig 8: Connecting Connector To Canister
    G10262340Courtesy of SUBARU OF AMERICA, INC.
  7. Connect the quick connectors of the vent tube (A), canister drain tube (B) and purge tube (C), and install the tube clamp (D).
    CAUTION:
    • Make sure there are no damage or dust on connections. If necessary, clean the seal surface of the pipe.
    • Make sure that the quick connector is securely connected.
    NOTE: Connect the quick connector as shown in the figure.
    • Vent tube (A) and canister drain tube (B) (Slider color is red or green.)
      Fig 9: Connecting Quick Connector (Slider Color Red Or Green)
      G11585882Courtesy of SUBARU OF AMERICA, INC.
    • Vent tube (A) and canister drain tube (B) (Slider color is white.)
      Fig 10: Connecting Quick Connector (Slider Color White)
      G11585883Courtesy of SUBARU OF AMERICA, INC.
    • Purge tube (C)
    Fig 11: Connecting Quick Connector
    G11585884Courtesy of SUBARU OF AMERICA, INC.
    Fig 12: Vent Tube, Canister Drain Tube And Purge Tube
    G10262339Courtesy of SUBARU OF AMERICA, INC.
  8. Install the rear mud guard LH. <Ref. to INSTALLATION , Mud Guard.>
  9. Lower the vehicle.
  10. Install the rear wheel LH. <Ref. to INSTALLATION , Tire and Wheel.>
  11. Connect the ground terminal to battery sensor. <Ref. to BATTERY , NOTE, Repair Contents.>