Diagnostic Method (Turbo Model)
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value | ||
|---|---|---|---|
| |Engine speed - Measured primary pulley shaft speed x Primary reduction gear ratio(1)| | < Table 4 RPM | ||
|
|||
ENGINE SPEED SPECIFICATION
| Engine speed (RPM) | 0 | 500 | 1000 | 1500 | 2000 | 2500 | 3000 | 3500 |
| |Engine speed - Measured primary pulley shaft speed x Primary reduction gear ratio| (RPM) | 0 | 0 | 50 | 50 | 50 | 50 | 50 | 50 |
| Engine speed (RPM) | 4000 | 4500 | 5000 | 5500 | 6000 | 6500 | 7000 |
| |Engine speed - Measured primary pulley shaft speed x Primary reduction gear ratio| (RPM) | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Time needed for diagnosis: 10 seconds
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.