LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Forester 2.0XT Touring >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) >> Refrigerant Pressure with Manifold Gauge Set >> Inspection >> High-Pressure Side Is High

High-Pressure Side Is High

  1. CHECK CONDENSER. 

    Check the condenser. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Condenser>INSPECTION .

    Is condenser OK?

    • Yes  : Go to  2.
    • No  : Clean or replace the condenser.
  2. CHECK RADIATOR FAN. 

    Check the radiator fan system.

    Is radiator fan system normal?

    • Yes  : Go to  3.
    • No  : Repair the radiator fan system or replace the faulty parts.
  3. FILL PROPER AMOUNT OF REFRIGERANT. 

Drain all refrigerant, and refill proper amount of refrigerant.

Is refrigerant pressure within the standard value?