Manual A/C Model
Control Module I/O Signal
- Control Module (i6)
Terminal No. Content Measuring condition Standard 1 FAN SW signal Blower fan is ON 1 V or less 2 A/C thermostat signal When blower fan is ON and A/C switch is ON 5 V or less 3 Intake door actuator (RECIRC) RECIRC mode 8 V or more 4 Intake door actuator (FRESH) FRESH mode 8 V or more 6 IGN Ignition switch ON Battery voltage 8 GND Always 1 V or less 9 RR DEF ON signal When the rear defogger switch is ON 1 V or less 10 RR DEF operating status signal Battery voltage 12 ILL- Illumination ON (measure between 12 - 14) Battery voltage 14 ILL+ - Blower fan switch (i5)
| Terminal No. | Content | Measuring condition | Standard |
|---|---|---|---|
| 1 | GND | Always | 1 V or less |
| 2 | LO (1st stage) | When blower fan switch 1 is used | 1 V or less |
| 3 | ML (2nd stage) | When blower fan switch 2 is used | 1 V or less |
| 4 | Blower fan ON signal | Blower fan is ON | 1 V or less |
| 5 | HI (4th stage) | When blower fan switch 4 is used | 1 V or less |
| 6 | MH (3rd stage) | When blower fan switch 3 is used | 1 V or less |