Air Conditioner Does Not Stop Even When The Off Switch Is Pressed
Trouble symptom:
Even when the OFF switch is pressed, the blower fan does not turn off, the inlet opening remains in FRESH mode, and the compressor does not turn off.
Trouble causes:
- CAN communication failure
- A/C control panel failure
- Blower motor failure
- Intake door actuator failure
- Compressor failure
- CHECK A/C CONTROL PANEL.
- Turn the ignition switch to ON.
- Press the OFF switch of the A/C control panel.
- Using Subaru Select Monitor, check the following data of the data monitor. Ref. to AIR CONDITIONER(DIAGNOSTICS)>Data Monitor .
- Blower Fan Level
- Fresh/Recircle Air Door Actuator Position Target
Does [Blower Fan Level] indicate 0, and [Fresh/Recircle Air Door Actuator Position Target] indicate 100%?
- Yes : Go to 2.
- No : Replace the A/C control panel. Ref. to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>Control Panel>REMOVAL .
- CHECK BLOWER MOTOR.
With the OFF switch pressed, check the blower motor operation.
Is the blower motor stopped?
- Yes : Go to 3.
- No : Ref. to AIR CONDITIONER(DIAGNOSTICS)>Diagnostics with Phenomenon>INSPECTION>AIR GOES OUT OF CONTROL .
- CHECK INTAKE DOOR ACTUATOR.
With the OFF switch pressed, check the FRESH/RECIRC door operation.
Does the FRESH/RECIRC door set to FRESH?
- Yes : Go to 4.
- No : Ref. to AIR CONDITIONER(DIAGNOSTICS)>Diagnostics with Phenomenon>INSPECTION>UNABLE TO SWITCH SUCTION VENTS .
- CHECK COMPRESSOR.
With the OFF switch pressed, check the compressor operation.
Is the compressor stopped?
- Yes
: The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- No : Ref. to AIR CONDITIONER(DIAGNOSTICS)>Diagnostics with Phenomenon>INSPECTION>COLD AIR DOES NOT COME OUT EVEN WHEN THE A/C SWITCH IS PRESSED. THE GLASS CANNOT BE DEFOGGED. (COMPRESSOR DOES NOT OPERATE.).
- Yes
: The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.