Data Monitor: List
| Items to be displayed | Unit of measure | Description | Note |
|---|---|---|---|
| In-vehicle Sensor Temperature | °C (°F) | A/C control panel input value | - |
| Quantity of Sunload | W/m2 | A/C control panel input value | - |
| A/C Pressure Switch | OK/NG | A/C control panel input value | - |
| Heater Water Temperature | °C (°F) | Data value received by CAN | - |
| Heater Control Panel Setting Value (Driver's) | LO: 18°C (60°F) HI: 32°C (90°F) |
Control panel display value | - |
| Heater Control Panel Setting Value (Passenger's) | LO: 18°C (60°F) HI: 32°C (90°F) |
Control panel display value | For models with left/right independent air conditioning function only |
| Blower outlet request temperature (Driver's) | °C (°F) | A/C control panel internal setting value | For models with left/right independent air conditioning function only |
| Blower outlet request temperature (Passenger's) | °C (°F) | A/C control panel internal setting value | For models with left/right independent air conditioning function only |
| Air mix door actuator position (driver's side) | % | A/C control panel input value | - |
| Air mix door actuator position (passenger's side) | % | A/C control panel input value | For models with left/right independent air conditioning function only |
| Mode Door Actuator Position | % | A/C control panel input value | - |
| Fresh/Recircle Air Door Actuator Position | % | A/C control panel input value | - |
| Target air mix door actuator position (driver's side) | % | A/C control panel input value | - |
| Target air mix door actuator position (passenger's side) | % | A/C control panel input value | - |
| Mode Door Actuator Position Target | % | A/C control panel input value | - |
| Fresh/Recircle Air Door Actuator Position Target | % | A/C control panel input value | - |
| Blower Fan Level | Level | A/C control panel internal output value | - |
| Ambient Air Temperature | °C (°F) | Data value received by CAN | - |
| Compressor operation status | OFF/AUTO | A/C control panel input value | - |
| Blower Fan Operating Condition | MANU/AUTO | A/C control panel input value | - |
| A/C Operating Condition | MANU/AUTO | A/C control panel input value | - |
| Fresh/Recircle Air Operating Condition | MANU/AUTO | A/C control panel input value | - |
| Mode Operating Condition | MANU/AUTO | A/C control panel input value | - |
| Rear Defogger | ON/OFF | A/C control panel input value | - |
| Engine Speed | RPM | Data value received by CAN | - |
| Vehicle Speed Sensor | km/h | Data value received by CAN | - |
| Evaporator Temperature | °C (°F) | A/C control panel input value | - |
| Evaporator Temperature Target | °C (°F) | A/C control panel input value | - |
| Blower outlet Door Request Temperature | °C (°F) | A/C control panel internal setting value | - |
| PTC permitted number | 0 - 3 | A/C control panel input value | Not supported |
| PTC operation steps | 0 - 3 | A/C control panel input value | Not supported |
| PTC Heater 3 | Inoperative/Operative | A/C control panel input value | Not supported |
| PTC Heater 2 | Inoperative/Operative | A/C control panel input value | Not supported |
| PTC Heater 1 | Inoperative/Operative | A/C control panel input value | Not supported |
| Request engine speed | 0: No request 1: Cooling H 2: Heating H 3: Cooling L 4: Heating L |
A/C control panel internal output value | - |
| Heater core Temp. | °C (°F) | A/C control panel input value | Not supported |