Item Specifications
Vehicle model Non-turbo model
CVT MT
Starter Type Reduction type
Model M000T38571 M000T33176
Manufacturer Mitsubishi Electric
Voltage and output 12 V -1.2 kW 12 V -1.0 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 9 8
No-load characteristics Voltage 11 V
Current 90 A or less 95 A or less
Generator Type Rotating-field three-phase type, voltage regulator built-in type, with load response control system
Model A5TV0081
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 150 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase < delta → type
Output current 1, 500 r/min- 44 A or more
2, 500 r/min- 121 A or more
5, 000 r/min- 148 A or more
Regulated voltage 14.0-14.6 V [20°C (68°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Brush length Standard 22.5 mm (0.886 in)
Limit 5.0 mm (0.197 in)
Battery Type 55D23L/75D23L
Nominal capacity 5 HR: 40 Ah [25°C (77°F)] (55D23L)/5 HR: 53 Ah [25°C (77°F)] (75D23L)
Nominal voltage 12 V
CCA 390 A (55D23L)/470 A (75D23L)
Item Specifications
Starter Type Reduction type
Model M000T20176
Manufacturer Mitsubishi Electric
Voltage and output 12 V -1.4 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 9
No-load characteristics Voltage 11 V
Current 90 A or less
Generator Type Rotating-field three-phase type, voltage regulator built-in type, with load response control system
Model A2TX3381
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 130 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase type
Output current 1, 500 r/min - 50 A or more
2, 500 r/min - 111 A or more
5, 000 r/min - 133 A or more
Regulated voltage 14.1-14.8 V [20°C (68°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Brush length Standard 22.5 mm (0.886 in)
Limit 5.0 mm (0.197 in)
Battery Type 55D23L/75D23L
Nominal capacity 5 HR: 40 Ah [25°C (77°F)] (55D23L)/5 HR: 53 Ah [25°C (77°F)] (75D23L)
Nominal voltage 12 V