LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Forester 2.0XT Touring >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 17 (Engine Control System (Diagnostics) (P0171 To P0685) (H4DO)) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P0616 Starter Relay "A" Circuit Low >> Model With Push Button Start

Model With Push Button Start

WARNING: This page is about a different variant/trim than selected.

Immediately at fault recognition

Trouble symptom: 

Failure of engine to start

CAUTION:

Wiring diagram: 

Engine Electrical System NON-TURBO MODEL (WITH PUSH BUTTON START) Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM>NON-TURBO MODEL (WITH PUSH BUTTON START) .

Fig 1: Starter Relay A Circuit Low - Wiring Diagram (Model With Push Button Start)
G11272672Courtesy of SUBARU OF AMERICA, INC.
  1. CHECK HARNESS BETWEEN ECM AND STARTER RELAY CONNECTOR  .
    1. Turn the ignition to OFF.
    2. Disconnect the connector from ECM.
    3. Remove the starter relay.
    4. Measure the resistance of harness between ECM connector and starter relay connector.
    NOTE: Place the select lever in "P" range or "N" range.

    Connector & terminal 

    (B134) No. 5 - (B225) No. 1:

    Is the resistance less than 1 Ω?

    • Yes: Go to 2  .
    • No: repair the harness and connector.
      NOTE: In this case, repair the following item:
      • Open circuit of harness between ECM connector and starter relay connector
      • Poor contact of coupling connector
  2. CHECK HARNESS BETWEEN ECM AND STARTER RELAY CONNECTOR  .
    1. Disconnect the connector from starter motor.
    2. Measure the resistance between ECM connector and chassis ground.

    Connector & terminal 

    (B134) No. 5 - Chassis ground:

    Is the resistance 1 MΩ or more?

    • Yes: Repair the poor contact of ECM connector.
    • No: Repair the short circuit to ground in harness between ECM connector and starter relay connector.
  3. OUTLINE OF DIAGNOSIS 
    • Model without push button start

      Detect abnormal continuity in the starter SW1.

      Judge as OFF NG when the starter SW 1 signal remains OFF.

    • Model with push button start

      Detect abnormal continuity in the starter SW 2.

      Judge as OFF NG when the starter SW 2 signal remains OFF.