DTC P0458 EVAP System (CPC) Purge Control Valve "A" Circuit Low: Notes
DTC detecting condition:
Detected when two consecutive driving cycles with fault occur.
Trouble symptom:
Improper idling
- After servicing or replacing faulty parts, perform Clear Memory Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Clear Memory Mode . and Inspection Mode Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Inspection Mode .
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK OUTPUT SIGNAL OF ECM
.
- Turn the ignition switch to ON.
- Measure the voltage between ECM connector and chassis ground.
Connector & terminal
(B135) No. 51 (+) - Chassis ground (-):
Is the voltage 10 V or more?
- Yes: Go to 2 .
- No: Go to 3.
- CHECK FOR POOR CONTACT
.
Check for poor contact of ECM connector.
Is there poor contact of ECM connector?
- Yes: Repair the poor contact of ECM connector.
- No: Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.NOTE: In this case, temporary open or short circuit of harness or temporary poor contact of connector may be the cause.
- CHECK POWER SUPPLY TO PURGE CONTROL SOLENOID VALVE
.
Measure the voltage between purge control solenoid valve connector and engine ground.
Connector & terminal
(E4) No. 1 (+) - Engine ground (-):
Is the voltage 10 V or more?
- Yes: Go to 4 .
- No: Repair the power supply circuit.
- CHECK HARNESS BETWEEN ECM AND PURGE CONTROL SOLENOID VALVE CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from the purge control solenoid valve.
- Disconnect the connector from ECM.
- Measure the resistance between the purge control solenoid valve connector and engine ground.
Connector & terminal
(E4) No. 2 - Engine ground:
Is the resistance 1 MΩ or more?
- Yes: Go to 5 .
- No: Repair the short circuit to ground in harness between ECM connector and purge control solenoid valve connector.
- CHECK HARNESS BETWEEN ECM AND PURGE CONTROL SOLENOID VALVE CONNECTOR
.
Measure the resistance of harness between ECM connector and purge control solenoid valve.
Connector & terminal
(B135) No. 51 - (E4) No. 2:
Is the resistance less than 1 Ω?
- Yes: Go to 6 .
- No: repair the harness and connector.NOTE: In this case, repair the following item:
- Open circuit in harness between ECM connector and purge control solenoid valve connector
- Poor contact of coupling connector
- CHECK PURGE CONTROL SOLENOID VALVE
.
- Remove the purge control solenoid valve.
- Measure the resistance between purge control solenoid valve terminals.
Terminals
No. 1 -No. 2:
Is the resistance 10 - 100 Ω?
- Yes: Repair the poor contact of purge control solenoid valve connector.
- No: Replace the purge control solenoid valve. Ref. to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (H4DO)>Purge Control Solenoid Valve .