DTC P0452 EVAP System (CPC) Pressure Sensor/Switch Circuit Low: Notes
DTC detecting condition:
Immediately at fault recognition
- After servicing or replacing faulty parts, perform Clear Memory Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Clear Memory Mode . and Inspection Mode Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Inspection Mode .
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK CURRENT DATA
.
- Turn the ignition switch to ON.
- Using the Subaru Select Monitor or a general scan tool, read the value of [Barometric Pressure].
NOTE:- Subaru Select Monitor
For detailed operation procedures, refer to "READ CURRENT DATA FOR ENGINE". Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Subaru Select Monitor .
- General scan tool
For detailed operation procedures, refer to the general scan tool operation manual.
Is the value in [Barometric Pressure] 34 kPa (255 mmHg, 10 inHg) or less?
- Yes: Go to 2 .
- No: Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK POWER SUPPLY OF LEAK CHECK VALVE ASSEMBLY
.
- Turn the ignition switch to OFF.
- Disconnect the connector from the leak check valve assembly.
- Turn the ignition switch to ON.
- Measure the voltage between the leak check valve assembly connector and chassis ground.
Connector & terminal
(R400) No. 6 (+) - Chassis ground (-):
Is the voltage 4.5 V or more?
- Yes: Go to 3 .
- No: repair the harness and connector.NOTE: In this case, repair the following item:
- Open circuit in harness between ECM connector and the leak check valve assembly connector
- Poor contact of ECM connector
- Poor contact of coupling connector
- CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the resistance between ECM connector and chassis ground.
Connector & terminal
(B134) No. 21 - Chassis ground:
Is the resistance 1 MΩ or more?
- Yes: Go to 4 .
- No: Repair the short circuit to ground in harness between ECM connector and leak check valve assembly connector.
- CHECK FOR POOR CONTACT
.
Check for poor contact of leak check valve assembly connector.
Is there poor contact in the leak check valve assembly connector?
- Yes: Repair the poor contact in the leak check valve assembly connector.
- No: Replace the leak check valve assembly. Ref. to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (H4DO)>Leak Check Valve Assembly .