Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Detect the trouble by calculating the response time of the rear oxygen sensor after fuel cut.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Time needed for rear oxygen sensor voltage to change from 0.3 V to 0.5 V | > 4000ms |
Time needed for diagnosis: Less than 1 second
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.