Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when Low side or High side becomes NG.
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Low Output voltage |
< Map 1 |
| High Output voltage |
≥ Map 2 |
MAP 1 SPECIFICATION
| Engine speed (RPM) | 1900 | 3000 | 4000 | 5000 | 6000 | 6800 |
|---|---|---|---|---|---|---|
| Output voltage (V) | 1.73 | 1.96 | 2.12 | 2.25 | 2.37 | 2.45 |
MAP 2 SPECIFICATION
| Engine speed (RPM) | 525 | 700 | 925 |
|---|---|---|---|
| Output voltage (V) | 1.69 | 1.83 | 1.97 |
Time needed for diagnosis:
Low: 5000ms
High: 5000ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.