Home >> Subaru >> 2017 >> Forester 2.0XT Touring >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 15 (Engine Control System (Diagnostics) (P2101 To U171F) (H4DO)) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P2271 O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 2 >> Notes

DTC P2271 O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 2: Notes

WARNING: This page is about a different variant/trim than selected.

DTC detecting condition: 

Detected when two consecutive driving cycles with fault occur.

CAUTION:

Wiring diagram: 

Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .

Fig 1: Engine Electrical System Wiring Diagram (Oxygen Sensor Signal Stuck Bank 1 Sensor 2)
G11272684Courtesy of SUBARU OF AMERICA, INC.
  1. CHECK REAR OXYGEN SENSOR CONNECTOR AND COUPLING CONNECTOR. 

    Has water entered the connector?

    • Yes: Completely remove any water inside.
    • No: Go to  2.
  2. CHECK HARNESS BETWEEN ECM AND REAR OXYGEN SENSOR CONNECTOR. 
    1. Turn the ignition switch to OFF.
    2. Disconnect the connector from rear oxygen sensor.
    3. Disconnect the connector from ECM.
    4. Measure the resistance of harness between ECM connector and rear oxygen sensor connector.

      Connector & terminal 

      (B135) No. 57 - (E25) No. 3:

      (B135) No. 56 - (E25) No. 4:

    Is the resistance less than 1 Ω? 

    • Yes: Go to  3.
    • No: repair the harness and connector.
      NOTE: In this case, repair the following item:
      • Open circuit in harness between ECM connector and rear oxygen sensor connector
      • Poor contact of coupling connector
  3. CHECK HARNESS BETWEEN ECM AND REAR OXYGEN SENSOR CONNECTOR. 

    Measure the resistance between ECM connector and chassis ground.

    Connector & terminal 

    (B135) No. 57 - Chassis ground:

    Is the resistance 1 MΩ or more?

    • Yes: Go to  4.
    • No: Repair the short circuit to ground in harness between ECM connector and rear oxygen sensor connector.
  4. CHECK EXHAUST SYSTEM. 

    Check exhaust system parts.

    NOTE: Check the following items.
    • Looseness and improper fitting of exhaust system parts
    • Damage (crack, hole etc.) of parts
    • Loose part and improper installation between front oxygen (A/F) sensor and rear oxygen sensor

    Is there any fault in exhaust system?