Monitor A1
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic value 1 (DV1) | > Threshold value 1 (TV1) |
MAP SPECIFICATION
| Charging efficiency (air mass %) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 70 | 80 | 90 | 100 | 110 | 120 | 140 | 160 | ||
| Engine speed (RPM) | 1500 | 0.001 | 0.001 | 0.002 | 0.005 | 0.004 | 0.004 | 0.004 | 0.004 |
| 2000 | 0.000 | 0.002 | 0.005 | 0.007 | 0.007 | 0.007 | 0.007 | 0.007 | |
| 2500 | 0.001 | 0.004 | 0.005 | 0.010 | 0.012 | 0.017 | 0.024 | 0.024 | |
| 3000 | 0.001 | 0.003 | 0.006 | 0.011 | 0.017 | 0.022 | 0.022 | 0.022 | |
| 3500 | 0.003 | 0.006 | 0.011 | 0.018 | 0.023 | 0.027 | 0.027 | 0.027 | |
| 4000 | 0.008 | 0.012 | 0.018 | 0.025 | 0.025 | 0.028 | 0.037 | 0.035 | |
Time needed for diagnosis: 10 seconds