DTC P2017 TGV Position Sensor/Switch Circuit High Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stalls.
- Poor driving performance
CAUTION:
- After servicing or replacing faulty parts, perform Clear Memory Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>Clear Memory Mode . and Inspection Mode Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>Inspection Mode .
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK CURRENT DATA.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed procedures, refer to "Data Monitor". Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>Subaru Select Monitor .
Is the value of [TGV Position Sensor R] 5 V or more?
- Yes : Go to 2.
- No
: Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR.
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve actuator RH.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].
NOTE: For detailed procedures, refer to "Data Monitor". Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>Subaru Select Monitor .Is the value of [TGV Position Sensor R] 5 V or more?
- Yes : Repair the short circuit to power in harness between ECM and tumble generator valve actuator RH connector.
- No : Go to 3.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR.
- Turn the ignition switch to OFF.
- Measure the resistance of harness between tumble generator valve actuator RH connector and engine ground.
Connector & terminal
(E55) No. 2 - Engine ground:
Is the resistance less than 5 Ω?
- Yes : Go to 4.
- No
: repair the harness and connector.NOTE: In this case, repair the following item:
- Open circuit in harness between ECM and tumble generator valve actuator RH connector
- Poor contact of ECM connector
- CHECK FOR POOR CONTACT.
Check for poor contact of tumble generator valve actuator RH connector.
Is there poor contact of the tumble generator valve actuator RH connector?
- Yes : Repair the poor contact of tumble generator valve actuator RH connector.
- No : Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DOTC)>Tumble Generator Valve Assembly .