Execution Condition
- Stuck
| Secondary Parameters | Execution condition |
|---|---|
| Ignition switch | ON |
| During switchover of regulating voltage | High condition judgment*1 ←→ Low condition judgment*2 However, the generator target duty has not experienced the following during switchover. 40% ≤ Generator target duty < 60 |
| *1 High condition judgment | |
| Continuous time during which all the conditions listed below are met | ≥ 5000 ms |
| circlef; Battery voltage | ≥ 13.7 V |
| circlef; Generator final output duty | ≥ 60 |
| circlef; Engine speed | ≥ 600 RPM |
| *2 Low condition judgment | |
| Secondary Parameters | Execution condition |
|---|---|
| Continuous time during which all the conditions listed below are met | ≥ 5000 ms |
| circlef; Battery voltage | < 13.2 V |
| circlef; Generator final output duty | < 40% |
| or | |
| circlef; Engine speed | 600 RPM |
- Characteristics malfunction
| Secondary Parameters | Execution condition |
|---|---|
| Ignition switch | ON |
| During switchover of regulating voltage | High condition judgment is established. Target duty ≥ 60% → target duty < 40% or Low condition judgment is established. Target duty < 40% → target duty ≥ 60 |