Execution Condition
| Secondary Parameters | Execution condition | ||
|---|---|---|---|
| (Common condition: Phase 1, Phase 2) | |||
| Battery voltage | ≥ 10.9 V | ||
| Barometric pressure | ≥ 75.06 kPa (563 mmHg, 22.2 inHg) | ||
| Fuel level | ≥ 9 L | ||
| <Phase 1> | |||
| Integrated purge air amount since engine starting | ≥ 72 g((1)) | ||
| Time of purge control duty ratio = 0% | ≥ 1 sec | ||
| Ambient air temperature | > 4.4°C and < 35°C (95°F) |
||
| Intake air amount per 1 second | > Map | ||
| High pressure purge line valve | Open | ||
|
|||
MAP SPECIFICATION
| Fuel level (%) | 15 | 17 | 33 | 50 | 67 | 83 | 100 |
| Fuel level (L) | 9 | 10 | 20 | 30 | 40 | 50 | 60 |
| Intake air amount per 1 second (g/s) | 80 | 80 | 60 | 60 | 60 | 60 | 60 |