Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Intake manifold pressure | > Value from Map |
MAP SPECIFICATION
| Atmospheric pressure kPa (mmHg, inHg) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 64 (480, 18.9) | 70.6 (529.5, 20.8) | 77.3 (579.8, 22.8) | 84 (630.1, 24.8) | 90.6 (679.6, 26.8) | 93.3 (699.8, 27.6) | 96 (720.1, 28.3) | 97.3 (729.8, 28.7) | ||
| Engine speed (RPM) | 1600 | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) | 204.7 (1535.6, 60.5) |
| 2400 | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | 223.7 (1677.9, 66.1) | |
| 3200 | 219.2 (1644.1, 64.7) | 223.3 (1674.9, 65.9) | 229.6 (1722.1, 67.8) | 233.7 (1752.9, 69) | 233.7 (1752.9, 69) | 233.7 (1752.9, 69) | 233.7 (1752.9, 69) | 233.7 (1752.9, 69) | |
| 4000 | 204.3 (1532.4, 60.3) | 210.7 (1580.4, 62.2) | 220.4 (1653.1, 65.1) | 236.4 (1773.2, 69.8) | 240.7 (1805.4, 71.1) | 240.7 (1805.4, 71.1) | 240.7 (1805.4, 71.1) | 240.7 (1805.4, 71.1) | |
| 4800 | 190.9 (1431.9, 56.4) | 201.9 (1514.4, 59.6) | 213.5 (1601.4, 63) | 234.7 (1760.4, 69.3) | 245.7 (1842.9, 72.6) | 245.7 (1842.9, 72.6) | 245.7 (1842.9, 72.6) | 245.7 (1842.9, 72.6) | |
| 5600 | 155.1 (1163.3, 45.8) | 176.5 (1323.9, 52.1) | 187.2 (1404.1, 55.3) | 208.6 (1564.6, 61.6) | 219.3 (1644.9, 64.8) | 234.3 (1757.4, 69.2) | 240.7 (1805.4, 71.1) | 240.7 (1805.4, 71.1) | |
| kPa (mmHg, inHg) | |||||||||
Time needed for diagnosis: 2000 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.