Diagnostic Method
Compare the diagnostic value with the threshold value, and if a condition meeting the criteria continues for 10 s x 3 times or more, judge that there is a fault in the fuel system.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Offset amount of main feedback amount | < Value from Map |
MAP SPECIFICATION
| Warm-up increase compensation coefficient | 0.00 | 0.10 | 0.20 | 0.30 | 0.33 | 0.50 | 0.60 |
|---|---|---|---|---|---|---|---|
| Threshold Value | 0.650 | 0.539 | 0.452 | 0.383 | 0.307 | 0.254 | 0.211 |
Time needed for diagnosis: 10 s x 3 times
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.