Unable To Perform The Reloading Operation (With Memory Function)
- CHECK MEMORY FUNCTIONS
.
Perform the memory operation of the seat position, and check the memory replay operation.
Does the seat position memory replay correctly?
- Yes: Memory function is normal. It is considered that the memory was cleared because the voltage falls below the operation-ensured voltage temporarily during memory restoration or manual operation. It operates normally by registering a memory.
- No: Go to 2 .
- CHECK MEMORY FUNCTIONS
.
At the memory operation of step 1, check the beep sound (once).
Was it possible to confirm the beep sound?
- Yes: Go to 3 .
- No: Perform the check item for "UNABLE TO SET POSITIONS INTO MEMORY". Ref. to SEATS>Power Seat System>INSPECTION>UNABLE TO SET POSITIONS INTO MEMORY (WITH MEMORY FUNCTION) .
- CHECK SWITCH
.
- Disconnect the connector of memory switch.
- Check memory switch. Ref. to SEATS>Power Seat System>INSPECTION>CHECK MEMORY SWITCH (WITH MEMORY FUNCTION) .
Is the inspection result normal?
- Yes: Go to 4 .
- No: Replace the memory switch assembly.
- CHECK HARNESS
.
- Disconnect the power seat control module connector.
- Measure the resistance between the memory switch connector and power seat control module.
Connector & terminal
(D143) No. 3 - (R155) No. 14:
(D143) No. 2 - (R155) No. 13:
(D143) No. 8 - (R155) No. 15:
Is the resistance less than 10 Ω?
- Yes: Go to 5 .
- No: Check power seat harness.
- CHECK COMBINATION METER
.
Turn the ignition switch to ON and check the indicator light inside the meter.
Does the indicator display "P"?
- Yes: Go to 6 .
- No: Check the combination meter. Ref. to INSTRUMENTATION/DRIVER INFO>Combination Meter System>INSPECTION .
- CHECK OPERATION
.
Operate all power seat switches to check operation of each motor.
Does each motor rotate for one second or more when operating each switch?
- Yes: Replace the power seat control module.
- No: Encoder defection. Replace the appropriate motor as a frame assembly.