Check Room Light Operation
- CHECK ROOM LIGHT OPERATION
.
Make sure the room light illuminates when the room light switch is ON, and goes off when the switch is OFF.
Does the room light illuminate or go off?
- Yes: Go to 2 .
- No: Check the room light circuit. Ref. to LIGHTING SYSTEM>Room Light>INSPECTION .
- CHECK ROOM LIGHT OPERATION
.
- Turn the room light switch to the "DOOR" position.
- Open and close any door.
Does the room light illuminate ←→ go off (including off delay) when the door is opened and closed?
- Yes: Go to 3 .
- No: Go to 4.
- CHECK KEYLESS ENTRY OPERATION
.
Press the LOCK/UNLOCK button of the keyless transmitter.
Does it operate properly?
- Yes: Room light is normal.
- No: Check keyless entry system. Ref. to SECURITY AND LOCKS>Keyless Entry System>INSPECTION>SYMPTOM CHART .
- CHECK ROOM LIGHT
.
Check the room light. Ref. to LIGHTING SYSTEM>Room Light>INSPECTION .
Is room light normal?
- Yes: Go to 5 .
- No: Replace the bulb or room light assembly.
- CHECK HARNESS
.
- Disconnect the connectors of body integrated unit and room light.
- Check the harness between body integrated unit and room light.
Connector & terminal
(i84) No. 4 - (R52) No. 2:
Is harness normal?
- Yes: Go to 6 .
- No: Repair or replace the harness.
- CHECK HARNESS
.
Measure the voltage between the room light connector and chassis ground.
Connector & terminal
(R52) No. 3 (+) - Chassis ground (-):
Is the voltage 10 V or more?
- Yes: Replace the body integrated unit. Ref. to SECURITY AND LOCKS>Body Integrated Unit .
- No: Repair or replace the harness.