| 0x01 |
+B Low Voltage |
The battery power supply of RAB CM is reduced. |
| 0x02 |
IGN Low Voltage |
The ignition power supply of RAB CM is reduced. |
| 0x03 |
RRC Sonar Noise |
Ultrasonic sensor (RRC) signal is interfered due to noise |
| 0x04 |
RLC Sonar Noise |
Ultrasonic sensor (RLC) signal is interfered due to noise |
| 0x05 |
RR Sonar Noise |
Ultrasonic sensor (RR) signal is interfered due to noise. |
| 0x06 |
RL Sonar Noise |
Ultrasonic sensor (RL) signal is interfered due to noise |
| 0x07 |
RRC Sonar Dirty HALT I |
Substance adhered to the ultrasonic sensor (RRC). |
| 0x08 |
RLC Sonar Dirty HALT I |
Substance adhered to the ultrasonic sensor (RLC). |
| 0x09 |
RR Sonar Dirty HALT I |
Substance adhered to the ultrasonic sensor (RR). |
| 0x0A |
RL Sonar Dirty HALT I |
Substance adhered to the ultrasonic sensor (RL). |
| 0x0B |
RRC Sonar Dirty HALT II |
Substance adhered to the ultrasonic sensor (RRC). |
| 0x0C |
RLC Sonar Dirty HALT II |
Substance adhered to the ultrasonic sensor (RLC). |
| 0x0D |
RR Sonar Dirty HALT II |
Substance adhered to the ultrasonic sensor (RR). |
| 0x0E |
RL Sonar Dirty HALT II |
Substance adhered to the ultrasonic sensor (RL). |
| 0x0F |
RRC Sonar Mount Error |
Ultrasonic sensor (RRC) is equipped with retrofitted items such as a rack and trailer. |
| 0x10 |
RLC Sonar Mount Error |
Ultrasonic sensor (RLC) is equipped with retrofitted items such as a rack and trailer. |