LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Forester 2.0XT Touring >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> LAN Communication System (Diagnostics) >> CAN Communication Circuit Check >> Procedure >> Wiring diagram

CAN Communication Circuit Check: Procedure: Wiring diagram

CAN communication system Ref. to WIRING SYSTEM>CAN Communication System>WIRING DIAGRAM .

Fig 1: CAN Communication System Wiring Diagram Non-Turbo Model (1 Of 2)
G11271390Courtesy of SUBARU OF AMERICA, INC.
Fig 2: CAN Communication System Wiring Diagram Non-Turbo Model (2 Of 2)
G11271391Courtesy of SUBARU OF AMERICA, INC.
Fig 3: CAN Communication System Wiring Diagram Turbo Model (1 Of 2)
G11271392Courtesy of SUBARU OF AMERICA, INC.
Fig 4: CAN Communication System Wiring Diagram Turbo Model (2 Of 2)
G11271391Courtesy of SUBARU OF AMERICA, INC.
  1. CHECK BASIC DIAGNOSTIC PROCEDURE. 

    Check that the basic diagnosis has been performed up to step 8.

    NOTE: Possible defective parts can be narrowed easily by inspection using Subaru Select Monitor before performing "CHECK CAN COMMUNICATION CIRCUIT" using a tester.

    Was the basic diagnostic procedure performed?

  2. CHECK FROM DATA LINK CONNECTOR. 

    Using the tester, measure the resistance between terminals.

    Connector & terminal 

    (B40) No. 6 - Chassis ground:

    (B40) No. 14 - Chassis ground:

    Is the resistance 10 Ω or less?

  3. CHECK FROM DATA LINK CONNECTOR. 
    1. Turn the ignition switch to ON.
    2. Using the tester, measure the voltage between terminals.

      Connector & terminal 

      (B40) No. 6 - Chassis ground:

      (B40) No. 14 - Chassis ground:

    Is the voltage 5 V or less?

  4. CHECK FROM DATA LINK CONNECTOR. 
    1. Turn the ignition switch to OFF.
    2. Using the tester, measure the resistance between terminals.

      Connector & terminal 

      (B40) No. 6 - No. 14:

    Is the resistance 52 Ω or less?

  5. CHECK FROM DATA LINK CONNECTOR. 

    Using the tester, measure the resistance between terminals.

    Connector & terminal 

    (B40) No. 6 - No. 14:

    Is the resistance 62 Ω or more?