Related Lines 53 - 61 Ω (Combination Meter): Wiring diagram
CAN communication system Ref. to WIRING SYSTEM>CAN Communication System>WIRING DIAGRAM .
- Non-turbo model
- Turbo model
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS.
- Disconnect the combination meter connector.
- Using the tester, measure the resistance between terminals.
Connector & terminal
(i10) No. 32 - No. 33:
Is the resistance 400 Ω or more?
- Yes : Related lines between combination meter and main wiring harness is open, or main wiring harness is open at two places or more.
- No : Go to 2.
- CHECK RELATED LINES.
Using the tester, measure the resistance between terminals.
Connector & terminal
(i10) No. 32 - (B40) No. 14:
(i10) No. 33 - (B40) No. 6:
Is the resistance 10 Ω or more?
- Yes : Repair or replace the open circuit of combination meter related lines.
- No : Check DTC of combination meter. Ref. to COMBINATION METER (DIAGNOSTICS)>Basic Diagnostic Procedure .