Home >> Subaru >> 2016 >> WRX Premium, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (Engine Controls (Diagnostics) (H4DOTC) (WRX-STI)) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P2440 Secondary Air System Switching Valve Stuck Open Bank 1 >> Wiring Diagram

DTC P2440 Secondary Air System Switching Valve Stuck Open Bank 1: Wiring Diagram

WARNING: This page is about a different variant/trim than selected.
DIAGNOSTIC PROCEDURE

Step Check Yes No
1 CHECK SECONDARY AIR COMBINATION VALVE FUSE. 
Check if the secondary air combination valve fuse (10 A) is blown out.
Is the fuse blown out? Go to step 2.  Go to step 3. 
2 CHECK HARNESS BETWEEN FUSE BOX AND SECONDARY AIR COMBINATION VALVE RH CONNECTOR. 
  1. Remove the secondary air combination valve fuse (10 A) from the fuse box.
  2. Disconnect the connector from the secondary air combination valve RH.
  3. Measure the resistance between the secondary air combination valve fuse and secondary air combination valve RH connector, and chassis ground.

    Connector & terminal 

    (F9) No. 5 - Chassis ground: 

    (E41) No. 2 - Chassis ground: 

Is the resistance 1 MΩ or more? Replace the fuse with a new part, and connect the secondary air combination valve RH connector. Go to step 3.  Repair the short circuit to ground in harness between the fuse box and the secondary air combination valve RH connector.
3 CHECK SECONDARY AIR COMBINATION VALVE RH OPERATION. 
  1. Install the delivery mode fuse.
  2. Turn the ignition switch to ON.
  3. Perform operation check for the secondary air combination valve RH using the Subaru Select Monitor.
    NOTE: For detailed operation procedures, refer to the "Active Test". < Ref. to ACTIVE TEST . >
Does the secondary air combination valve RH repeatedly switch to ON and OFF? Go to step 4.  Go to step 6. 
4 CHECK DUCT BETWEEN SECONDARY AIR PUMP AND SECONDARY AIR COMBINATION VALVE RH. 
Check the duct between the secondary air pump and secondary air combination valve RH.
Is there damage, clog or disconnection of the duct? Replace, clean or connect the duct. Go to step 5. 
5 CHECK PIPE BETWEEN SECONDARY AIR COMBINATION VALVE RH AND CYLINDER HEAD. 
Check the pipe between the secondary air combination valve RH and cylinder head.
Is there damage, clog or disconnection of the pipe? Replace, clean or connect the pipe. Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
6 CHECK POWER SUPPLY TO SECONDARY AIR COMBINATION VALVE RH. 
  1. Disconnect the connector from the secondary air combination valve RH.
  2. In the condition of step 3, measure the voltage between secondary air combination valve RH connector and chassis ground.

    Connector & terminal 

    (E41) No. 2 (+) - Chassis ground (-): 

Does the voltage repeatedly change between 10 V and 0 V? Replace the secondary air combination valve RH. < Ref. to SECONDARY AIR COMBINATION VALVE . > Go to step 7. 
7 CHECK HARNESS BETWEEN SECONDARY AIR COMBINATION VALVE RH AND CHASSIS GROUND. 
Measure the resistance between the secondary air combination valve RH connector and chassis ground.
Connector & terminal 
(E41) No. 1 - Chassis ground: 
Is the resistance less than 5 Ω? Go to step 8.  Repair the open circuit in harness between secondary air combination valve RH connector and chassis ground.
8 CHECK HARNESS BETWEEN SECONDARY AIR COMBINATION VALVE RELAY 2 AND SECONDARY AIR COMBINATION VALVE RH CONNECTOR. 
  1. Turn the ignition switch to OFF.
  2. Remove the secondary air combination valve relay 2 from the relay box.
  3. Measure the resistance of the harness between secondary air combination valve relay 2 connector and secondary air combination valve RH connector.

    Connector & terminal 

    (F9) No. 8 - (E41) No. 2: 

Is the resistance less than 1 Ω? Go to step 9.  Repair the harness and connector.
NOTE: In this case, repair the following item:
  • Open circuit in harness between secondary air combination valve relay 2 connector and secondary air combination valve RH connector
  • Poor contact of coupling connector
9 CHECK SECONDARY AIR COMBINATION VALVE RELAY 2. 
  1. Connect the battery to terminals No. 9 and No. 10 of the secondary air combination valve relay 2.
  2. Measure the resistance between the secondary air combination valve relay 2 terminals.

    Terminals 

    No. 7 - No. 8: 

Is the resistance less than 1 Ω? Go to step 10.  Replace the secondary air combination valve relay 2. < Ref. to ELECTRICAL COMPONENT LOCATION . >
10 CHECK SECONDARY AIR COMBINATION VALVE RELAY 2. 
Measure the resistance between the secondary air combination valve relay 2 terminals with the battery disconnected.
Terminals 
No. 7 - No. 8: 
Is the resistance 1 MΩ or more? Go to step 11.  Replace the secondary air combination valve relay 2. < Ref. to ELECTRICAL COMPONENT LOCATION . >
11 CHECK SECONDARY AIR COMBINATION VALVE RELAY 2 POWER SUPPLY. 
  1. Turn the ignition switch to ON.
  2. Measure the voltage between the secondary air combination valve relay 2 connector and chassis ground.

    Connector & terminal 

    (F9) No. 7 (+) - Chassis ground (-): 

    (F9) No. 10(+) - Chassis ground (-): 

Is the voltage 10 V or more? Go to step 12.  Repair the open or short to ground in the power supply circuit.
12 CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY 2 CONNECTOR. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the ECM connector.
  3. Measure the resistance of harness between ECM connector and secondary air combination valve relay 2 connector.

    Connector & terminal 

    (B135) No. 20 - (F9) No. 9: 

Is the resistance less than 1 Ω? Go to step 13.  Repair the harness and connector.
NOTE: In this case, repair the following item:
  • Open circuit in harness between ECM connector and secondary air combination valve relay 2 connector
  • Poor contact of coupling connector
13 CHECK HARNESS BETWEEN ECM AND SECONDARY AIR COMBINATION VALVE RELAY 2 CONNECTOR. 
Measure the resistance between the secondary air combination valve relay 2 connector and chassis ground.
Connector & terminal 
(F9) No. 9 - Chassis ground: 
Is the resistance 1 MΩ or more? Repair the poor contact of ECM connector. Repair the short circuit to ground in harness between ECM connector and secondary air combination valve relay 2 connector.