Power Will Not Turn On (Both Accessory And Ignition)
CAUTION:
- When the keyless access CM (Control Module) is replaced with a new unit, and the battery ground terminal is connected, it will become ignition ON. Also, if the battery is disconnected, it will resume to a condition with the battery cut off.
- When the keyless access CM (Control Module) is replaced, registration of the immobilizer is required. For the relevant procedures, refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK FUSE. Check the fuse. < Ref. to RELAY AND FUSE . > |
Is the fuse OK? | Go to step 2. | Replace the fuse. |
2 CHECK POWER SUPPLY.
|
Is the voltage 10 V or more? | Go to step 3. | Check the DC power supply circuit. |
| 3 CHECK CONNECTOR. Check the engagement of each connector and for any deformation or looseness. |
Are the connectors and terminals normal? | Go to step 4. | Repair the connector, or replace harness. |
4 CHECK WIRING HARNESS.
|
Is the voltage between 8 V and 16 V? | Go to step 5. | Repair or replace the open circuit of harness. |
| 5 CHECK WIRING HARNESS. Using a tester, check continuity between the keyless access CM (Control Module) connector and chassis ground. Connector & terminal (B572) No. 11 - Chassis ground: |
Is there continuity? | Go to step 6. | Repair or replace the open circuit of harness. |
6 CHECK DTC.
|
Is a DTC output? | Perform diagnosis according to the DTC. | Go to step 7. |
7 CHECK CURRENT DATA.
|
Does it change from OFF to ON along with the operation? | Go to step 8. | Go to step 15. |
| 8 CHECK RELAY (PUSH BUTTON START). Check IG relay 1 and 2 (push button start), and accessory relay (push button start). < Ref. to INSPECTION , IG Relay1 (Push Button Start). > |
Is each relay normal? | Go to step 9. | Replace the faulty relay. |
9 CHECK WIRING HARNESS.
|
Is there continuity? | Go to step 10. | Repair or replace the open circuit of harness. |
| 10 CHECK WIRING HARNESS. Using a tester, check continuity between the keyless access CM (Control Module) connector and chassis ground. Connector & terminal (B572) No. 9 - Chassis ground: (B574) No. 4 - Chassis ground: (B574) No. 6 - Chassis ground: |
Is there continuity? | Repair or replace the short circuit of the harness. | Go to step 11. |
| 11 CHECK WIRING HARNESS. Using a tester, check the continuity between the IG relay 2 (push button start) connector and chassis ground. Connector & terminal (B225) No. 39 - Chassis ground: |
Is there continuity? | Go to step 12. | Repair or replace the open circuit of harness. |
| 12 CHECK WIRING HARNESS. Using a tester, check the continuity between the IG relay 1 connector and chassis ground. Connector & terminal (B225) No. 35 - Chassis ground: |
Is there continuity? | Go to step 13. | Repair or replace the open circuit of harness. |
| 13 CHECK WIRING HARNESS. Using a tester, check the continuity between the accessory relay connector and chassis ground. Connector & terminal (B426) No. 2 - Chassis ground: |
Is there continuity? | Go to step 14. | Repair or replace the open circuit of harness. |
14 CHECK KEYLESS ACCESS CM (Control Module).
|
Did the voltage change from 1 V or less to +B-2 V or more? | Go to step 15. | Replace the keyless access CM (Control Module). < Ref. to KEYLESS ACCESS CM (Control Module) . > |
15 CHECK PUSH BUTTON IGNITION SWITCH.
|
When the button was pressed, did it change to continuity exists? (No continuity when button is released) | Go to step 16. | Replace the push button ignition switch. < Ref. to REMOVAL , Push Button Ignition Switch. > |
| 16 CHECK WIRING HARNESS. Using a tester, check the continuity between the push button ignition switch connector and chassis ground. Connector & terminal (i150) No. 4 - Chassis ground: (i150) No. 5 - Chassis ground: |
Is there continuity? | Go to step 17. | Repair or replace the open circuit of harness. |
17 CHECK WIRING HARNESS.
|
Is there continuity? | System is normal. | Repair or replace the open circuit of harness. |