DTC U1650 Invalid Data Received From Meter (UART): Wiring Diagram
Clearance Light and Illumination Light System Ref. to the appropriate SYSTEM WIRING diagram article.
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK LAN SYSTEM. Read the DTC of body integrated unit and LAN system using Subaru Select Monitor. < Ref. to OPERATION , Read Diagnostic Trouble Code (DTC). > < Ref. to OPERATION , Read Diagnostic Trouble Code (DTC). > |
Is any DTC other than U1650 displayed? | Perform the diagnosis according to DTC. | Go to step 2. |
| 2 CHECK FUSE. Check the fuse No. 31 in the fuse & relay box. |
Is the fuse OK? | Go to step 3. | Replace the fuse. When the fuse is blown easily, check the wiring. |
3 CHECK HARNESS.
|
Is the voltage 10 V or more? | Go to step 4. | Repair the ACC power supply circuit of the body integrated unit. |
4 CHECK CURRENT DATA OF INTEGRATED UNIT.
|
Is the voltage 10 V or more? | Go to step 5. | Inspect and correct the body integrated unit connector. If there is no abnormality, replace the body integrated unit. < Ref. to BODY INTEGRATED UNIT . >(There may be a poor contact in the body integrated unit connector ((B280) terminal No. 32), or an internal malfunction of the integrated unit.) (If the current data indicates ACC voltage value ≈ Battery voltage, there will be no malfunction up to inside of the integrated unit. If U1650 is still detected in this condition as current malfunction, perform step 5 and subsequent procedures.) |
5 CHECK CONNECTOR.
|
Is DTC U1650 a current malfunction? | Go to step 6. | There was poor contact of connector. Repair the poor contact of connector. (Poor contact in combination connector (i10) terminal No. 20 or MFD connector (i122) terminal No. 9) |
6 CHECK COMBINATION METER.
|
Is DTC U1650 a current malfunction? | Replace the MFD. < Ref. to MULTI-FUNCTION DISPLAY (MFD) . > | There was something wrong with the combination meter. |