- On «Main Menu» display, select {Each System Check}.
- On «Each System Check» display, select {HEV System}.
- On «HEV System» display, select {Drive Motor Control System}.
- On «Drive Motor Control System» display, select {Work Support}.
- On «Work Support» display, select {System Operation Check Mode}.
| Items under system operation check mode | Display | Note | |
|---|---|---|---|
| High Voltage Battery Cooling Fan | Target Output Mode | Stop Step1 Step2 Step3 |
Perform high voltage battery cooling fan compulsory drive. Example of use: Used to check high voltage battery cooling fan circuits. |
| High Voltage Battery Cooling Fan Speed | 0 - 6000 | rpm | |
| Drive Motor Inverter power supply relay | Target Output Mode | OFF ON |
Perform high voltage battery cooling fan/drive motor inverter power supply relay compulsory drive. Example of use: Used to check operation of high voltage battery cooling fan/drive motor inverter power supply relay. |
| Drive Motor Inverter Operation Update Signal Count (Serial) | 0 - 255 | Count | |
NOTE:
The conditions listed below must be met to perform the mode.
| Display of current data | Value |
|---|---|
| Ignition switch | ON |
| ECU ACC | 11.0 V or more |
| Drive Motor Inverter Operation Signal(HPCM) | OFF |
| Contactor Open Status | Open |
| High Voltage Battery Cooling Fan Duty Target (HPCM) | 0% |