Monitor Strategy
WARNING: This page is about a different variant/trim than selected.
| Applicable diagnostic codes | P0961: Pressure Control Solenoid "A" Control Circuit Range/Performance P0962: Pressure Control Solenoid "A" Control Circuit Low P0963: Pressure Control Solenoid "A" Control Circuit High |
| Required sensor/component | Clutch control solenoid No. 1 (SL1) |
| Operation frequency | Consecutive |
| Period | P0961: 2 count P0962: 0.1 seconds X5 times P0963: 0.1 seconds X5 times |
| MIL operation | Immediate |
| Operation order | None |