Low-Pressure Side Is Low
DIAGNOSTIC PROCEDURE
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK REFRIGERANT LEAKAGE
. Check the refrigerant for leakage. <Ref. to INSPECTION , Refrigerant Leak Check.>
NOTE:
When the pressure on the high-pressure side is less than 0.69 Mpa: Go to Step 2.
|
Are there any refrigerant leakage? | Repair the refrigerant leakage. | Go to step 2 . |
| 2 FILL PROPER AMOUNT OF REFRIGERANT
. Drain the refrigerant completely, and then refill the proper amount of refrigerant. |
Is the refrigerant pressure within the specified range? | Refrigerant pressure is normal. | Go to step 3 . |
| 3 REPLACE EXPANSION VALVE
. Replace the expansion valve. <Ref. to REMOVAL , Expansion Valve.> |
Is the refrigerant pressure within the specified range? | Refrigerant pressure is normal. | Inspect the compressor. <Ref. to COOL AIR DOES NOT COME OUT WHEN PRESSING THE A/C SWITCH. FOG CANNOT BE CLEARED. (COMPRESSOR DOES NOT OPERATE.) , DIAGNOSTIC PROCEDURE WITH PHENOMENON, Diagnostics with Phenomenon.> |