  1. Install the PCV valve to the PCV connector and connect the vacuum hose (A) to the PCV valve.
    NOTE: Apply liquid gasket to the bolt threads of PCV valve.

    Liquid gasket: 

    THREE BOND 1324 (Part No. 004403042) or equivalent 

    Tightening torque: 

    22.5 N.m (2.3 kgf-m, 16.6 ft-lb) 

    Fig 1: Locating Vacuum Hose Clamp
    G08539032Courtesy of SUBARU OF AMERICA, INC.
  2. Install the intercooler. <Ref. to INSTALLATION , Intercooler.>