LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2015 >> WRX Limited, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Fuel Injection System (STI)) >> Wastegate Control Solenoid Valve >> Inspection >> WASTEGATE Control Solenoid Valve

WASTEGATE Control Solenoid Valve

WARNING: This page is about a different variant/trim than selected.
  1. Check that the wastegate control solenoid valve has no deformation, cracks or other damages.
  2. Check the resistance between the wastegate control solenoid valve terminals.
    Fig 1: Checking Resistance Between Wastegate Control Solenoid Valve Terminals
    G06344717Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Standard
    1 and 2 28±2 Ω (when 20°C (68°F))
  3. Check that air does not come out from (B) when air is blown into (A).
    Fig 2: Checking Air Blow Off Between Wastegate Control Solenoid Valves
    G06344718Courtesy of SUBARU OF AMERICA, INC.
  4. Connect the battery positive terminal to the terminal No. 1 and the battery ground terminal to the terminal No. 2. Check that air is discharged from (B), when supplying air to (A).
Fig 3: Connecting Battery Positive Terminal To Terminal No 1 And Battery Ground Terminal
G06344719Courtesy of SUBARU OF AMERICA, INC.