Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG when Monitor A1 and Monitor B1 are both NG, and when either is OK, judge as OK.
Monitor A1
Judge as NG when the following conditions are established.
Judgment Value
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic value 1 (DV1) | > Threshold value 1 (TV1) |
Map
ENGINE LOAD SPECIFICATION - MAP
| Engine load (g/rev (oz/rev)) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 0.8 (0.03) | 0.9 (0.03) | 1 (0.04) | 1.1 (0.04) | 1.2 (0.04) | 1.3 (0.05) | 1.4 (0.05) | 1.5 (0.05) | ||
| Engine speed (rpm) | 1600 | 0.0069 | 0.0088 | 0.0073 | 0.0078 | 0.0080 | 0.0081 | 0.0087 | 0.0087 |
| 1800 | 0.0077 | 0.0084 | 0.0074 | 0.0072 | 0.0076 | 0.0074 | 0.0074 | 0.0074 | |
| 2000 | 0.0074 | 0.0079 | 0.0077 | 0.0080 | 0.0082 | 0.0087 | 0.0087 | 0.0087 | |
| 2200 | 0.0060 | 0.0081 | 0.0088 | 0.0061 | 0.0056 | 0.0061 | 0.0059 | 0.0059 | |
| 2400 | 0.0059 | 0.0065 | 0.0073 | 0.0082 | 0.0062 | 0.0063 | 0.0067 | 0.0073 | |
| 2600 | 0.0036 | 0.0053 | 0.0064 | 0.0051 | 0.0079 | 0.0078 | 0.0068 | 0.0071 | |
| 2800 | 0.0045 | 0.0042 | 0.0046 | 0.0056 | 0.0063 | 0.0062 | 0.0076 | 0.0081 | |
| 3000 | 0.0062 | 0.0062 | 0.0073 | 0.0075 | 0.0073 | 0.0081 | 0.0071 | 0.0078 | |
| 3200 | 0.0049 | 0.0066 | 0.0073 | 0.0073 | 0.0076 | 0.0076 | 0.0079 | 0.0079 | |
Time Needed for Diagnosis: 4 ms x 2500 time(s)
Monitor B1
Judge as NG when the following conditions are established.
Judgment Value
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnostic Value2 (DV2) | > 14 time(s) |
Time Needed for Diagnosis: 500 engine revs.
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.