Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as NG if the criteria below are met.
Diagnosis 1
Judgment Value
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Output duty to drive circuit | ≥ 95 % |
Time Needed for Diagnosis:
- Engine speed ≥ 500 rpm: 2000 ms
- Engine speed < 500 rpm: 5000 ms
Diagnosis 2
Judgment Value
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Difference between target opening angle and actual opening angle | Within NG range of Details of Judgment value |
Time Needed for Diagnosis:
- Engine speed ≥ 500 rpm: Refer to Details of Judgment time.
- Engine speed < 500 rpm: 5000 ms
Details of Judgment Value
Details of Judgment time
NOTE:
Judgment time is always 1000 milliseconds when actual opening angle < target opening angle.
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.