Home >> Subaru >> 2015 >> WRX Limited, Automatic CVT Trans >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrumentation System & Driver Information Center (Diagnostics) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC U1650 Invalid Data Received From Meter (UART) >> Wiring Diagram

DTC U1650 Invalid Data Received From Meter (UART): Wiring Diagram

Clearance Light and Illumination Light System <Ref. to INTERIOR LIGHTS , Clearance Light and Illumination Light System.>

Fig 1: Clearance Light And Illumination Light System Wiring Diagram
G10270911Courtesy of SUBARU OF AMERICA, INC.
DIAGNOSTIC PROCEDURE

Step Check Yes No
1 CHECK LAN SYSTEM  .
Read the DTC of body integrated unit and LAN system using Subaru Select Monitor. <Ref. to READ DIAGNOSTIC TROUBLE CODE (DTC) .> <Ref. to READ DIAGNOSTIC TROUBLE CODE (DTC) .>
Is any DTC other than U1650 displayed? Perform the diagnosis according to DTC. Go to step .
2 CHECK FUSE  .
Check the fuse No. 31 in the fuse & relay box.
Is the fuse OK? Go to step . Replace the fuse. When the fuse is blown easily, check the wiring.
3 CHECK HARNESS  .
  1. Disconnect the body integrated unit connector.
  2. Turn the ignition switch OFF → ACC.
  3. Measure the voltage between body integrated unit connector and chassis ground using tester.

    Connector & terminal 

    (B280) No. 32 (+) - Chassis ground (-): 

Is the voltage 10 V or more? Go to step . Repair the ACC power supply circuit of the body integrated unit.
4 CHECK CURRENT DATA OF INTEGRATED UNIT  .
  1. Connect the Subaru Select Monitor.
  2. Turn the ignition switch to ON.
  3. Check the current data «ACC voltage» of the body integrated unit. <Ref. to READ CURRENT DATA .>
Is the voltage 10 V or more? Go to step . Inspect and correct the body integrated unit connector. If there is no abnormality, replace the body integrated unit. <Ref. to BODY INTEGRATED UNIT .> (There may be a poor contact in the body integrated unit connector ((B280) terminal No. 32), or an internal malfunction of the integrated unit.) (If the current data indicates ACC voltage value ≈ Battery voltage, there will be no malfunction up to inside of the integrated unit. If U1650 is still detected in this condition as current malfunction, perform step 5 and subsequent procedures.)
5 CHECK CONNECTOR  .
  1. Disconnect the MFD connector and the combination meter connector.
  2. Connect the disconnected connectors.
  3. Read the DTC of the MFD using the Subaru Select Monitor. <Ref. to READ DIAGNOSTIC TROUBLE CODE (DTC) .>
Is DTC U1650 a current malfunction? Go to step . There was poor contact of connector. Repair the poor contact of connector. (Poor contact in combination connector (i10) terminal No. 20 or MFD connector (i122) terminal No. 9)
6 CHECK COMBINATION METER  .
  1. Replace the combination meter. <Ref. to COMBINATION METER .>
  2. Read the DTC of the MFD using the Subaru Select Monitor. <Ref. to READ DIAGNOSTIC TROUBLE CODE (DTC) .>
Is DTC U1650 a current malfunction? Replace the MFD. <Ref. to MULTI-FUNCTION DISPLAY (MFD) .> There was something wrong with the combination meter.