Illumination Control Switch
- Measure the resistance between connector terminals.
Preparation tool:
Circuit tester
Courtesy of SUBARU OF AMERICA, INC.
Terminal No. Inspection conditions Standard 1 - 6 Bright switch OFF 10 kΩ or more Bright switch ON Less than 1 Ω 4 - 6 Always 4465 to 4935 Ω 5 - 6 Illumination control switch upward fully open 475 to 525 Ω Illumination control switch downward fully open 4370 to 4830 Ω - Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.
Terminal No. Inspection conditions Specification 2 (+) - 3 (-) Apply battery voltage. Light ON - Replace the illumination control switch if the inspection result is not within the standard value.