| [In-vehicle Sensor Temperature] |
Vehicle compartment temperature is displayed. Display range: -72.47 to 193.82°C {-98.4 to 380.9°F} |
Default value is displayed for open or short-circuit. [SSM3] (25°C {77°F}) is displayed. |
Cooler thermistor (in-vehicle sensor) system |
| [Quantity of Sunload] |
Light strength at the sunload sensor is displayed. Display range: 0 to 4448 W/m2 |
In the range from 0 to 4448, it is increased for brighter light (the value according to sunload is displayed).
- Default value is displayed for open circuit, no sunload or short-circuit: (0) is displayed.
|
Automatic light control sensor system |
| [A/C Pressure Switch] |
Refrigerant pressure is displayed. Display range: Normal - Abnormal |
Refrigerant pressure status is displayed. |
Compressor assembly operation Refrigerant level Refrigerant leak Pressure switch system |
| [Heater Water Temperature] |
Driver's seat side setting temperature is displayed. Display range: -40.00 to 215.00°C {-40.00 to 419.00°F} |
In the range from -40.00 to 215.00°C {-40.00 to 419.00°F}, the engine coolant temperature is displayed. |
Engine is warmed. E.F.I. water temperature (coolant temperature sensor) system CAN communication system |
| [Heater Control Panel Setting Value (Driver's)] |
Driver's seat side setting temperature is displayed. Display range: 15.00 to 90.00°C {59.00 to 194.00°F} |
The same value as the setting temperature display is displayed. |
When the driver's seat side setting temperature dial is operated Control panel system |
| [Heater Control Panel Setting Value (Passenger's)] |
Passenger's seat side setting temperature is displayed. Display range: 15.00 to 90.00°C {59.00 to 194.00°F} |
The same value as the setting temperature display is displayed. |
When the passenger's seat side setting temperature dial is operated Control panel system |
| [Blower outlet request temperature (Driver's)] |
Target temperature of the driver's seat side outlet opening is displayed. Display range: -327.68 to 327.67°C {-557.82 to 621.80°F} |
- In MAX COLD: -327.68°C {-557.82°F} is displayed.
- In MAX HOT: 327.67°C {621.80°F} is displayed.
|
- |
| [Blower outlet request temperature (Passenger's)] |
Target temperature of the passenger's seat side outlet opening is displayed. Display range: -327.68 to 327.67°C {-557.82 to 621.80°F} |
- In MAX COLD: -327.68°C {-557.82°F} is displayed.
- In MAX HOT: 327.67°C {621.80°F} is displayed.
|
- |
| [Air mix door actuator position (driver's side)] |
Actual position information of the driver's seat side air mix damper is displayed. Display range: -32.68 to 133.33 % |
The target opening is followed. |
Air mix damper servo system |
| [Air mix door actuator position (passenger's side)] |
Actual position information of the passenger's seat side air mix damper is displayed. Display range: -32.68 to 133.33 % |
The target opening is followed. |
Air mix damper servo system |
| [Mode Door Actuator Position] |
Actual position information of the mode damper is displayed. Display range: -32.68 to 133.33 % |
The target opening is followed. |
Mode damper servo system |
| [Fresh/Recircle Air Door |
Actuator Position] Actual position information of the FRESH/RECIRC damper is displayed. Display range: 0 to 100 % |
The target FRESH/RECIRC position is followed.
- In REC: 0 %
- In FRS: 100 %
|
Damper servo (FRESH/RECIRC) system |
| [Target air mix door actuator position (driver's side)] |
Actual position information of the driver's seat side air mix damper is displayed. Display range: -32.68 to 133.33 % |
- In MAX COOL: -10 is displayed.
- In MAX HOT: 100 is displayed.
|
Air mix damper servo system |
| [Target air mix door actuator position (passenger's side)] |
Actual position information of the passenger's seat side air mix damper is displayed. Display range: -32.68 to 133.33 % |
- In MAX COOL: 0 is displayed.
- In MAX HOT: 110 is displayed.
|
Air mix damper servo system |
| [Mode Door Actuator Position Target] |
Actual position information of the mode damper is displayed. Display range: -32.68 to 133.33 % |
- In FACE: -16.7
- In B/L: 10
- In FOOT: 70
- In FOOT/DEF: 90
- In DEF: 116.7
|
In operation of the outlet opening switch Mode damper servo system |
| [Fresh/Recircle Air Door Actuator Position Target] |
Position information of the FRESH/RECIRC damper is displayed. Display range: REC - FRS |
|
In operation of the FRESH/RECIRC switch Damper servo (FRESH/RECIRC) system |
| [Blower Fan Level] |
The revolution level of the blower fan motor is displayed. Display range: 0 to 31 |
When the revolution is increased, the value goes up in the range from 0 to 31.
- In Min: 0 is displayed.
- In Max: 31 is displayed.
|
Blower fan system |
| [Ambient Air Temperature] |
Ambient air temperature is displayed. Display range: -40.00 to 80.00°C {-40.00 to 176.00°F} |
Value immediately before or default value (15.2°C {59.4°F}) is displayed when there is open or short-circuit. |
Cooler thermistor (ambient sensor) system |
| [Compressor operation status] |
Compressor assembly Display range: OFF - ON |
- In compressor OFF: OFF
- In compressor ON: ON
|
Compressor assembly operation |
| [Blower Fan Operating Condition] |
Operation mode (manual/auto) of the blower fan is displayed. Display range: Manual - Auto |
- In manual: Manual
- In Auto: Auto
|
- |
| [A/C Operating Condition] |
Operation mode (manual/auto) of the compressor is displayed. Display range: Manual - Auto |
- In manual: Manual
- In Auto: Auto
|
Engine control computer system |
| [Fresh/Recircle Air Operating Condition] |
Operation mode (manual/auto) of FRESH/RECIRC is displayed. Display range: Manual - Auto |
- In manual: Manual
- In Auto: Auto
|
In operation of the FRESH/RECIRC switch Damper servo (FRESH/RECIRC) system |
| [Mode Operating Condition] |
Operation mode (manual/auto) of the outlet opening is displayed. Display range: Manual - Auto |
- In manual: Manual
- In Auto: Auto
|
Mode damper servo system |
| [Rear Defogger] |
Rear defogger switch status is displayed. Display range: OFF - ON |
- Switch OFF: OFF
- Switch ON: ON
|
- |
| [Engine Speed] |
Display range: 0 to 32767 |
In the range from 0 to 32767, the engine speed is displayed. |
- |
| [Vehicle Speed] |
Display range: 0.00 to 300.00 |
In the range from 0.00 to 300.00, the vehicle speed is displayed. |
- |
| [Evaporator Temperature] |
Evaporator ambient temperature is displayed. Display range: -82.48 to 153.55°C {-116.46 to 308.39°F} |
- In open circuit: (-82.48°C {-116.46°F}) is displayed.
- In short-circuit: (153.55°C {308.39°F}) is displayed.
|
Cooler thermistor NO. 1 (after-evaporator sensor) system |
| [Evaporator Temperature Target] |
Cooler thermistor NO. 1 (after-evaporator sensor) target temperature is displayed (target value of ECM). Display range: 0.00 to 20.00°C {32.00 to 68.00°F} |
In the range from 0.00 to 20.00, the target after evaporator temperature is displayed. |
Cooler thermistor NO. 1 (after-evaporator sensor) system |
| [Intake port auto mode] |
Set value of initial RECIRC is displayed. Display range: Manual - Auto |
- In manual: Manual
- In Auto: Auto
|
Customize setting |
| [Compressor auto mode] |
Set value of compressor Auto is displayed. Display range: Without interlock - With interlock |
- In manual: Manual
- In Auto: Auto
|
Customize setting |
| [Intake port (PSW, lock) linkage] |
Set value of inlet opening (PSW/lock) interlock is displayed. Display range: Without interlock - With interlock |
- Without interlock: No interlock
- With interlock: Interlock
|
Customize setting |
| [Foot/DEF Automatic Blow Up Function] |
Set value of air flow increase in DEF is displayed. Display range: Without increase - With increase |
- Without increase: No increase
- With increase: Increase
|
Customize setting |
| [FOOT/DEF auto mode] |
Set value of FOOT/DEF interlock is displayed. Display range: Manual - Auto |
- In manual: Manual
- In Auto: Auto
|
Customize setting |
| [Setting temperature shift] |
Setting temperature shift value is displayed. Display range: -3 to +3°C |
Setting temperature shift is displayed. |
Customize setting |
| [Number of Diagnostic Code(s):] |
Display range: 0 to 255 |
Number of diagnostic codes output is displayed. |
- |