LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Legacy Premium, Automatic CVT Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) >> Relay and Fuse >> Inspection >> Check Relay

Check Relay

  1. Measure the resistance between blower motor relay terminals.
    Terminal No. Inspection conditions Standard Circuit
    1 - 4 Always 1 MΩ or more
    G06652930
    1 - 4 Apply battery voltage between terminals 2 and 3. Less than 1 Ω
  2. Replace the blower motor relay if the inspection result is not within the standard value.