HVAC Control Systems
>>
HVAC System (Heater, Ventilator And A/C)
>>
Relay and Fuse
>>
Inspection
>>
Check Relay
Check Relay
Measure the resistance between blower motor relay terminals.
Terminal No.
Inspection conditions
Standard
Circuit
1 - 4
Always
1 MΩ or more
1 - 4
Apply battery voltage between terminals 2 and 3.
Less than 1 Ω
Replace the blower motor relay if the inspection result is not within the standard value.