LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Legacy Premium, Automatic CVT Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) >> Refrigerant Pressure with Manifold Gauge Set >> Inspection >> High And Low Pressure Sides Are Equal, Or High-Pressure Side Is Low

High And Low Pressure Sides Are Equal, Or High-Pressure Side Is Low

Step Check Yes No
1 CHECK REFRIGERANT LEAKS. 
Check the refrigerant for leaks. Refer to INSPECTION .
NOTE: When high-pressure side is less than 0.69Mpa: Go to step 2.
Are there refrigerant leaks? Repair the refrigerant leaking points. Go to step .
2 FILL PROPER AMOUNT OF REFRIGERANT. 
Drain all refrigerant, and refill proper amount of refrigerant.
Is refrigerant pressure within the standard value? Refrigerant pressure is normal. Inspect the compressor. Refer to COLD AIR DOES NOT COME OUT EVEN WHEN THE A/C SWITCH IS PRESSED. THE GLASS CANNOT BE DEFOGGED (COMPRESSOR DOES NOT OPERATE (VARIABLE)) .