Heater System

Item Specifications Condition
Heating capacity 4.8 kW (4, 127 kcal/h, 16, 377 BTU/h) or more
  • Air flow control switch: FOOT
  • Temperature control switch or dial: HI (MAX HOT)
  • Temperature difference between hot water and inlet air: 65°C (149°F)
  • Hot water flow rate: 360 L (95.1 US gal, 79.2 Imp gal)/h
Air flow rate 300 m3 (10, 596 cu ft)/h FOOT mode (FRESH), MAX HOT at 12.5 V
Max air flow rate 495 m3 (17, 483 cu ft)/h
  • Temperature control switch or dial: LO (MAX COOL)
  • Fan switch or dial: HI (MAX)

    Auto A/C model: 6th position

    Manual A/C model: 4th position

  • FRESH/RECIRC switch: RECIRC
Heater core size (height x length x width) 264 x 100 x 27 mm (10.4 x 3.94 x 1.06 in) -
Blower motor Type Magnet motor 260 W or less 12 V
Fan type and size (diameter x width) Sirocco fan type 150 x 75 mm (5.91 x 2.95 in) -