Evaporator Sensor: Inspection

Preparation tool: 

Subaru Select Monitor III kit 

Circuit tester 

Thermometer and hygrometer 

  1. Prepare the vehicle.
    NOTE: Check that the ambient temperature is 25 - 40°C (77 - 104°F) and that the humidity is 30% - 80%.
    • Place the vehicle in the workshop or in the shade and windless condition.
    • Open all windows.
  2. Set the vehicle to the following conditions.
    Item Condition
    Engine Idling
    Air vent grille Shutter is fully open.
    AC switch OFF
    Temperature control switch or dial LO (MAX COOL)
    FRESH/RECIRC switch CIRC
    Air flow control switch VENT
    Fan switch (auto A/C model) 4 - 6 levels
    Fan dial (manual A/C model) 3 - 4 levels
  3. Using the Subaru Select Monitor, check the evaporator sensor.
    1. Prepare the Subaru Select Monitor kit.
    2. Run the "PC application for Subaru Select Monitor".
    3. On «Main Menu» display, select {Each System Check}.
    4. On «System Selection Menu» display, select {Air Condition System}.
    5. On «Air Conditioning Diagnosis» display, select {Current Data Display & Save}.
    6. Select {Evaporator Temperature} with UP/DOWN key and set with the [OK] key.
    7. Idle the engine for 15 minutes, and then compare the outlet opening temperature with {Evaporator Temperature Target}.
      NOTE: For outlet opening temperature, measure the average temperature of center grille assembly and side grille assembly.
    8. Is the difference between outlet opening temperature and {Evaporator Temperature Target} by 3°C (5.4°F) or more?
      • Yes  → Go to step 4).
      • No  → Evaporator sensor is normal.
  4. Perform the inspection of evaporator sensor unit.
    1. Disconnect the evaporator sensor connector.
    2. Is the resistance between terminals of evaporator sensor within standard value?
      Fig 1: Checking Resistance Between Evaporator Sensor Terminals 1 And 2
      G08546108Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Inspection conditions Standard
    1 - 2 -20°C 13.584 - 14.541 kΩ
    -15°C 10.34 - 10.946 kΩ
    -10°C 7.938 - 8.313 kΩ
    -5°C 6.143 - 6.366 kΩ
    0°C 4.79 - 4.914 kΩ
    5°C 3.718 - 3.829 kΩ
    10°C 2.889 - 3.031 kΩ
    15°C 2.247 - 2.435 kΩ
    20°C 1.785 - 1.952 kΩ
    25°C 1.427 - 1.574 kΩ
    30°C 1.149 - 1.278 kΩ
    35°C 0.931 - 1.044 kΩ
    40°C 0.759 - 0.858 kΩ
    • Yes  → Evaporator sensor is normal.
    • No  → Replace the evaporator sensor.