Blower Switch (Manual A/C Model)
Preparation tool: Circuit tester
- Check the resistance between terminals of the control panel.
Terminal No. Inspection conditions Standard Connection diagram - OFF - - 1 - 2, 4 1 (LO) Less than 1 Ω 1 - 3, 4 2 (M1) Less than 1 Ω 1 - 4, 6 3 (M2) Less than 1 Ω 1 - 4, 5 4 (HI) Less than 1 Ω - Replace the control panel if the inspection result is not within the standard value.